The danger posed by static electricity when
filling or discharging material from Type C Flexible
Intermediate Bulk Containers (FIBCs) is controlled
by a system expressly designed for these
applications. The Earth-Rite FIBC grounding
system from Newson Gale Inc. constantly
monitors Type C containers, (often known as
SuperSacks) ensuring that the containers’ anti-static
features are, in fact, within the correct
specificaions and achieving a positive ground
connection.
While Type C containers feature a conductive
construction to deal with static build-up they do
not provide positive assurance that build-up will
not occur since external factors might also be
involved. For example, the grounding clamp may
not be attached properly or the conductive fibers
of the bag damaged in prior use. And it is also
possible that the FIBC itself may not be
appropriate for the application at hand.
The Earth-Rite FIBC system provides verification that the bag’s anti-static construction is functional
and that it is, in fact, correctly grounded. The interlock design will allow product transfer only when the
resistance through the container is less than 1x10 8 Ohms. While Type C FIBC applications are most
common, the system can also be used to monitor similar static dissipative materials such as drum linings,
kegs, hoses, etc.
Should unacceptable readings be registered an alarm signal LED is lighted and the system remains
inoperable, ensuring that safe operating procedures are followed. Readings are taken through a special
insulated monitoring clamp attached to the conductive ground loop of the FIBC. To suit various types of
filling/discharging machinery the system is offered in two formats: one which monitors resistance between
the grounded lifting loops and a clamp attached to ground, and another monitoring resistance between
two separate clamps with respect to ground. Since the Earth-Rite FIBC system is ATEX approved
intrinsically safe it is suitable for use in virtually all potentially explosive atmosphere zones. The
monitoring unit is EX rated II 1 GD EEx ia IICT4 and the power supply II (1) GD [EExia] IIC, with FM
pending.
The Earth-Rite FIBC static grounding system is just part of the Cenelectrex® range of static
grounding and bonding equipment available from Newson Gale Inc., the Lakewood, NJ based specialists
in static control for hazardous areas.
For additional information, contact: Newson Gale Inc., 1072 Madison Ave., Lakewood, NJ 08701.
Phone: 732-987-7715. E-Mail: info@newson-gale.com. Website: www.newson-gale.com |