Benefits:
-
Enables hazardous area operators demonstrate Best Practice compliance with Cenelec CLC/TR: 50404.
-
Resistance monitoring system, combined with machine interlocking output contacts (x2), ensures operators correctly clamp and ground the bag before filling or emptying can commence.
-
While the process is underway the system continuously monitors the resistance of the bag ensuring static charges have a safe static dissipative path to the plant earth ground.
-
Red and pulsing Green LED indicators tell operators whether or not a good ground connection is made.
-
FIBC Stainless steel clamp and system enclosure suitable for Zone 21, Zone 2, Class I, II, III, Div. 2.
-
Zone 1 and Class I, II, III, Div. 1 options available.
|
|

The Earth-Rite FIBC system monitors the resistance across the system's clamp (bottom of bag) and the second clamp (top of bag), back to the system's plant earth grounding point connection.
|
|
CLC/TR: 50404 states the following in relation to the static hazards associated with powder filling and emptying of FIBCs:
“Electrostatic charge can be generated during filling and emptying and it can accumulate on the product as well as on the fabric from which a FIBC is constructed or on any parts of it. An ignition could occur if the accumulated charge is released in the form of an incendive discharge in the presence of a flammable atmosphere. Spark, brush, cone and propagating brush discharges are all possible when FIBC are used." (CLC/TR: 50404).
|